Iei-integration NANO-LX v1.10 Uživatelský manuál Strana 223

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 232
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 222
NANO-LX EPIC SBC
ENTER.
Step 2: The Data on RAID drives will be erased (Y/N) confirm box appears. Press Y.
Step 0:
E.5.7 Rebuild RAID Array
The Rebuild RAID Array option can rebuild a RAID array if a member of a RAID
configuration should fail. Neither RAID0 nor JBOD provides data redundancy. The
Rebuild RAID Array option only applies to RAID1 arrays and is applicable when a
member of a RAID1 configuration has failed.
Step 1: Use the arrow keys to highlight Rebuild RAID Array and press E
NTER. A
flashing ‘R’ appears at the list of existing arrays. The source and destination
drives will be displayed.
Step 2: Press Y to begin the rebuild process. Step 0:
NOTE:
A status bar will indicate the rebuild progress. Rebuild consumes
considerable system resources and the time required for rebuilding a RAID
array may vary depending on the size of stored data, disk drive capacity, and
drive performance.
E.5.8 Select Boot Drive
Step 1: Use the arrow keys to highlight Select Boot Drive and press ENTER. A flashing
‘A’ appears at the Drive Menu where the boot drive can be chosen.
Step 2: Press E
NTER or the space bar to finish the configuration. Step 0:
Page 223
Zobrazit stránku 222
1 2 ... 218 219 220 221 222 223 224 225 226 227 228 ... 231 232

Komentáře k této Příručce

Žádné komentáře