PICOe-HM650 Half-size PCIe CPU Card
Page 50
WARNING:
Do not wipe off the thermal paste on the bottom of the heatsink. The
thermal paste allows the maximum heat dissipation.
To install the cooling kit, please follow the steps below.
Step 1: Install the support bracket. Remove the tape from the support bracket. From
the solder side of the board, align the support bracket to the holes on board and
stick in place.
Figure 4-4: Install Support Bracket
Step 2: Properly orient the cooling kit. The CPU fan cable must not interfere with the
fan or other moving parts. Make sure the cable can be routed away from the
moving parts.
Step 3: Properly align the cooling kit. Line up the four screws with the screw holes on
the support bracket below the board (
Figure 4-5).